More FAQs about
Marine System
Plumbing Joining, Solvents... no, they're not Cements Related Articles: Plumbing Marine Systems,
Plumbing
Return Manifolds, Refugiums,
Related FAQs: Marine Plumbing 1, Marine
Plumbing 2, Marine Plumbing 3, Marine
Plumbing 4, Marine Plumbing 5, Marine
Plumbing 6, Plumbing 7, Plumbing
8, Plumbing 9, Plumbing
10, Plumbing 11, Plumbing
12, Plumbing 13, Plumbing
14,
Plumbing 15,
Plumbing 16,
Plumbing 17,
Plumbing 18,
Plumbing
19,
Plumbing
20,
& FAQs on:
Plans/Designs, Parts:
Pipe, Valves,
Back-Siphon/Check-Valves,
Unions, Tools,
Use of Flexible
Tubing, Leaks/Repairs, &
Holes & Drilling,
Durso Standpipes, Overflow Boxes,
Bubble Trouble,
Plumbing Noise, Make Up
Water Systems,
Pumps, Plumbing,
Circulation, Sumps,
Refugiums, Marine
Circulation 2, Gear
Selection for Circulation, Pump
Problems, Fish-Only
Marine Set-ups, Fish-Only
Marine Systems 2, FOWLR/Fish and
Invertebrate Systems, Reef Systems, Coldwater
Systems, Small Systems, Large
Systems, Water Changes, Surge
Devices,
|
.JPG)
Solvents are toxic... until "liberated"... that is until they
evaporate... Open those windows if using indoors... Octopus cyanea
|
Plumbing... toxicity? PVC/solvent compatibility 3/12/08
Hello Crew,
I recently plumbed a sump/refugium below my tank. I primed and cemented
<Solvented...>
everything with Oatey Purple Primer and All Purpose Cement. On the first day I
made the U-tube for the return and hung the overflow working my way down. On day
two I finished my drain line, hung my U-tube and finished the return. I let
everything sit overnight and started everything up the next day after work.
<Good to be methodical here>
Everything worked great, there were no leaks, it was beautiful. I sat there for
the longest time staring at it, feeling like I really accomplished something.
Everything looked fine before I left for work the next morning. When I returned,
however, I returned to a horrible chemical smell, and found all of my fish on
their sides breathing rapidly. Not like the cement smells, it was much worse. I
acted quickly with carbon, water changes, and disconnected all of my plumbing. I
only lost a Six Line Wrasse. All of the difficult fish and corals unbelievably
made it through. After disconnecting the pipes, which we
re PVC by the way, I was sure that that was the source by the smell. I let the
pipes dry for a day. Then I filled the bath tub with vinegar and warm water,
letting it sit overnight. The next day I ran warm tap water through them and the
past two days they've been drying out. The problem is that they smell like
cement again and I'm a little scared to try them now. When I hung my U-tube
<... what is this made of? Are you sure it's PVC?>
the end was submerged in my display, so I'm not sure if that may have kept the
fumes in the pipe and effected the curing or what really caused this. So my
question is, do you think it is safe to try this again? I may have mixed a
little of the primer with the cement while it was still wet,
<Mmm, this is not the protocol of using these products (yes, there's even
instructions, plumbing code outline for solventing, priming plastic pipe!)...
See the cans' instructions>
but at the time I didn't think it would matter. Now I don't really know where I
went wrong. Retracing my steps, that's about all that I can think of. The bottle
recommended two hours of curing time, which it had and then some. I was just
about to buy all new parts, so I could start from scratch, but I figured I would
see what you guys think first. Thanks for taking the time to answer my
long-winded question, I just wanted to be descriptive for all who read this.
Thanks, Jeff
<Jeff... do please send along a pic or two... Esp. of the U-tube... is this
polyvinyl chloride? Bob Fenner>Re: plumbing, PVC solvent smell,
issue – 03/13/08
I am sure the U-tube is PVC.
<Yes... I see this in your excellent photographs>
I made it out of 90 degree elbows and short lengths of PVC pipe. It was
just a starting point for plumbing my return. When I said I may have
mixed the primer with the cement/solvent (bottle says cement),
<I do understand, agree... Will try to explain. Cements imply that
"something" is left/making the "joint" twixt surfaces... My point/intent
is to state that these materials actually act as solvents... melting the
PVC together...>
I meant that after applying the cement I noticed the applicator was a
little purple.
<Which is okay... is colored to help/make sure that the applicator (you,
I) know where and that we have applied it... there are color-less
primers that some commercial folks use... and many friends/associates
who are disdainful of using primer at all (I'm not one of them)...
Relying on the cleanliness, new-ness of the pipe, fittings, and the
solvent/cement to make the joints alone>
I did allow time for the primer to dry, but maybe a drop rolled to the
bottom and went unnoticed.
<Shouldn't be an issue>
I don't know for sure. I did not deliberately mix the two. I also
thought it may have just been a result of the cement/solvent reacting
with the now purple PVC. I am new to plumbing, but I did try to follow
the instructions on the bottle. I will probably use the green "Heavy
Duty" type solvent next time to avoid this problem all together.
<Agreed... I do use a bunch of this... or the Christy's "Super Hot Blue"
solvent... in dirty, wet applications... instead of the thinner, clear
or grey products.>
Here are the pictures that you requested. It's not much to look at in
the tub, but it looks good when it's set up.
Thanks, Jeff
<Looks like a good job... And, really, there should be little to no
residual smell... and no dangerous chemical activity/reactions once the
joints are an hour or more old, air-exposed... I would rinse them in
freshwater, and use at this point. Cheers, Bob Fenner> |
|
 |
Super Glue or PVC Solvent? - 06/30/07
Hi Folks,
<<Hello>>
I am uncertain whether I can or must use PVC compound to secure fittings or
whether Super Glue (cyanoag) works as well???
<<Trust me here my friend...use a proper PVC cleaner and solvent. EricR>>
Can I Use Epoxy To Patch PVC Leaks? –
06/07/07
Hi guys! Jason here from Manila.
<<Greetings Jason...Eric from SC here>>
Hope you are having fun.
<<I’m breathing at least...>>
I'm done PVC cementing my pipes, and will be checking for leaks soon enough.
<<Okay>>
If I have a particular piping structure that I do not want to rebuild from
scratch because it has a leak,
<<May not have a choice here>>
what are my other alternatives to patch the leak?
<<None really...is always best to cut-out/replace the offending connection>>
Will using epoxy glue be sufficient to patch a leak permanently?
<<Likely not, in my opinion. You could try swabbing or injecting some PVC
cement at the leak but this rarely works, especially for the long-term. But
no need to “rebuild from scratch,” (you did plan/allow for this by leaving a
bit of extra pipe length between the joints?), just cut out/replace the
leaky bit and leave the rest be>>
Also, I'm thinking of getting a TR15 Teco chiller for my 90 gallon tank -
I've discussed via email about the flow-rates for the chiller with some Teco
technicians.. they assured me that there is no efficiency loss as long as I
am running the chiller with a pump who's
flow rate is from 100 to 790 gallons.
<<I saw these units at the IMAC in Chicago this past weekend...appeared very
well made, quiet, and efficient units>>
I was thinking of running my Eheim 1260 (635 gallons) thru my chiller and
back up to my display as my return pump.
<<This is how my chiller is plumbed>>
Should I get a smaller pump?
<<I see no reason to, no>>
Thanks,
Jason
<<Happy to share. EricR>>
Connecting Overflow PVC with Silicone Only? 5/20/07
Hello Crew! Jason here from Manila. Hope all is well with you.
<Yes my friend, thank you>
I've read on your FAQs how you support using silicone (vs. cement) on
threaded PVC fittings, as you can easily pull it out when you wish.
<Yes... make a nice, cushioned seat...>
I have PVC going out of my overflow bulkheads, that I would like to use
Silicone (vs. cement) as I will have an extremely difficult time removing it
if the pieces are cemented together.
<Yes... have to be cut, replaced if solvented...>
I am not able to get threaded fittings, unless I make my tubing bulky with
extra PVC pieces (which I do not want to do if I can help it). So I have
slip PVC pieces. Can silicone provide a proper seal on slip PVC pieces?
<Mmm, no... too likely these joints will pull apart>
I am not running any pumps thru these.
The water running thru here is from my overflow, into my sump.
Hope you guys can help!
Jason
<Perhaps looking for, using "unions" (a type of re-joinable PVC fitting)
will work out better for you here. Bob Fenner>
Is Silicone the Savior for Sealing? ...Mmm,
Depends On the Application - 04/27/07
Hi Guys, Jason here from Manila.
<<Greetings Jason...Eric here from warm and muggy South Carolina>>
I've read your FAQs and noted how you guys like to use just silicone on
threaded PVC to make a nice seal.
<<Many do, yes...but I prefer Teflon tape for this>>
And it can be undone, unlike PVC solvent.
<<Yes...but then, it doesn't make any sense to me to use threaded
fittings if you plan to use solvent glue>>
I'm making my closed-loop circulation, and I've used PVC solvent on the
slip joints.
<<As you should...>>
If I find a leak in one of the joints, can I seal it with a dab of
silicone, or must I start over and recreate everything.
<<If a solvent-welded joint begins to leak you are better off cutting it
out/replacing the joint altogether. The silicone does not really
"adhere" to the PVC and even though it may stop the leak
temporarily...it will eventually fail>>
I've got to recreate everything, because I can't just "undo" PVC
solvent.
<<Correct>>
Also, can I use just silicone on PVC slip joints, out of water?
<<Nope...need to be solvent welded>>
My other question involves bulkheads. My buddy here uses bulkheads from
the local hardware store, female and male joint. No gaskets, just
silicone smeared on the joints, and on both sides of the glass to
provide as the gasket.
<<I see>>
Is this a good sealed joint, or do you guys suggest gaskets?
<<I prefer to use a gasket (provided with the bulkheads I purchase)>>
If so, what kind, and on both sides?
<<An EPDM rubber or neoprene gasket should suffice. I place the single
gasket under the flange on the wet side of the bulkhead and use a smear
of silicone on the dry side to seat the nut>>
Thanks!
Jason
<<A pleasure to share. Eric Russell>>
Tank Plumbing...Pipe Diameter/Joint Sealing -
04/02/07
Hi Guys!
<<Hello Jason>>
I am building a closed-system with SCWD for circulation after reading
many of your FAQs and articles.
<<Hmm...I think you mean a "closed-loop">>
You guys are great!
<<Glad you think so>>
I hope you can help with some plumbing questions that I tried searching
for on your FAQs.
<<I shall try>>
I may be getting an Eheim pump... If the output valve is 3/4", after
reading your FAQs, you've said the piping should be a bit bigger. Will
1" piping be fine for a 3/4" valve?
<<It will>>
I also read that you guys suggest flexible hose piping to the valves to
reduce vibration.
<<Yes>>
Can I just use a clamp with your suggested silicone on the valves?
<<You can, yes...but if you are using the pump in a "submerged" fashion
I don't feel you need the silicone>>
When connecting joints that slip, is it fine just to use Silicone to
create a seal .. or must I use PVC solvent?
<<Use PVC solvent. Done correctly this will make a permanent watertight
seal, and if you make a mistake...is cheap to "redo">>
Seems to me that if joints are threaded together, you suggest silicone.
<<Ah yes, for "threaded" PVC joints the silicone will do fine...and also
allow the connections to be undone when/if necessary. Though
personally, with the exception of seating/sealing bulkhead fittings, I
prefer to use Teflon tape for threaded joints...is quick and easy to
apply/reapply with no waiting for silicone to cure>>
Thanks guys!
Jason
<<Happy to share. EricR>>
PVC Glues, actually solvents... - 02/22/07
Hello again and sorry for being such a pest, but, I live 40 minutes away
from the nearest half decent aquatic store, work weekends and have school on the
weekdays.
<No worries! Always time for the hobby right?>
Anyway... I have been constructing a framework for the rocks in my reef tank
using pvc pipe and was wandering if it is safe to use a pvc pipe adhesive?
<My understanding is if it's safe for drinking water it should be safe for the
fish tank. I generally use the purple stuff ...that is the technical name
right?>
The one which I have contains Bisphenol a-epichlorohydrin epoxy resin.
<I'm not familiar, looked it up on the net and I'm still not familiar, but if it
is used for tap water, it should be OK.>
I don't want to poison my fish but I also don't want to have my rocks collapse
and fall through the glass....
<Both bad scenarios, though one is less messy!>
Thank you once again.
<Any time! -Mich>
Will
Plumbing Glue - 12/28/06
When plumbing a tank, is it all right to use regular PVC glue like that used
for plumbing homes?
Thanks,
Ellen
<<Yes indeed, it is quite safe for your wet pets. Do let the joints "cure" for
a bit before running water through them...I find about 15 minutes to be
sufficient. EricR>><RMF likes to let cure for a day...>
PVC Glue "run" time 6/13/06
Quick question regarding "dry time" for PVC solvent:
You stated:
"Oh, and waiting a good hour before running water in newly solvented lines is
about right in terms of curing time. Okay?"
I notice fumes that are really overpowering and have been giving my fittings
DAYS for the smell to go away. Is this not harmful to the aquarium? Or am I
missing something?
<Can be, could be... though I suspect the "after smell" is largely
psychological>
I most certainly would love to be able to use the new fittings sooner than
later.
Thanks...
Bruce Webster
<There is a wide-range in PVC "solvents"... cure times... I am a big fan of
"Christy's Super Hot Blue", and Green (heavy-bodied) "Landscaper" solvents...
but many, likely most folks use clear, lower viscosity Weld-On... with
(hopefully) or w/o their "purple" primer (comes in clear as well, but the purple
is nice to assure you've applied it). When, where in doubt, I would wait for
actual use of solvented plumbing, but do read the manufacturer's recommendation
posted on the container. Bob Fenner, who for many years, waited about an hour
for up to 2 inch pipe, fittings... >
Liquid Teflon
I recently put a sump together with food grade pails and PVC piping and have
spent the last week trying to stop leaks. Finally, I used Oatey's Great White
pipe joint compound with Teflon, replacing the Teflon tape, and seems to have
done the job. It is supposed to be non-toxic and non-separating, but it does not
dry or harden, and has a strong smell. It lists hydrocarbon oils as
an ingredient. I have used on 3 joints out of many, and theoretically
the water will have very little or no contact with the paste. The
total system including sumps holds about 300 gallons of water (net of fish, rock
and corals). How concerned concerned should I be about contamination?
Thanks a lot,
Ron
<I would NOT use/trust this material on biological systems. Instead, if
there's a possibility of draining, drying all joints, try a smear of 100%
silicone sealant (any color, just sans the mildewcides for tub/sink
applications) on both sides of threads and gaskets... and allow a day or so to
cure. Bob Fenner>
PVC glue
Hi All,
Quick plumbing question. Is there a major difference using the 2 part
primer and cement for gluing PVC plumbing, or can I just use
"Christy's" PVC cement which is a purple one part cement that doesn't
require the primer?? Also, maybe a silly question, but I imagine once
it dries, this cement is non-toxic, correct?? There is no way to apply without
getting some that will be exposed to water. Thanks.
<No, no major difference. Make sure you clean pipe ends and fittings well.
Yes, it actually welds the pipe together. Apply a thin coat evenly to
each part and twist when assembling, hold together for about a minute to prevent
the reaction of the glue from forcing the joint apart. Wipe out as much excess
glue as possible. Let cure 24 hours with plenty ventilation. Should be fine
after that. Craig>
Sealing joint material choices
I'm planning to replace the hoses on my trickle filter to pvc pipes. what is
the best kind of bond materials would you recommend, to seal the joints
together?
>>
PVC to PVC, weld-on solvents (light bodied) up to 2" diameter... if the pipe isn't new, clean, do use a "purple" colored primer to clean them up ahead of time. PVC to flexible? Threaded to barbed connectors and doubled nylon snap clamps...
Bob Fenner
Plumbing
I want to hard plumb my filter system. Does it matter what type of pipes I use? Will the glue that you use to put the pipes together harm the fish? Also, what type of UV filter would you
recommend for 100 gallon tank? Thank You!
<See the "Plumbing" pieces on the Marine and Pond Indexes on our website: www.WetWebMedia.com... most folks use PVC or ABS of the various formulations used... and the solvents have no effect as they're "gone" when the plumbing is in use... some slight toxicity from these plastics, no big deal. UVs are also covered on the FAQs section of the same name on the WWM site. Happy reading. Bob
Fenner>
| |
|